Jurnal Internasional Afrika vol.12 issue 4 2022
African Journal of Emergency Medicine
An observational simulation-based study of the accuracy of intercostal drain placement and factors influencing placement

Dublin Core

Title

Jurnal Internasional Afrika vol.12 issue 4 2022
African Journal of Emergency Medicine
An observational simulation-based study of the accuracy of intercostal drain placement and factors influencing placement

Subject

Chest tubes Thoracostomy Clinical competence Intercostal drain Complications

Description

Introduction: South Africa’s significant burden of trauma and respiratory disease requires the regular need for intercostal drain (ICD) insertion. ICD misplacement is associated with significant complications. The aim of this study was to assess ICD insertion site accuracy and the factors affecting accuracy by Emergency Department doctors. Methods: This was a prospective, observational simulation-based study. Prior to participant admission, pertinent thoracic structures were marked on two simulated patients using an invisible marker which could only be seen using ultraviolet light. One by one, study participants were then asked to place a sticker on each side of each patient’s chest to indicate where they would insert an ICD. Sticker placements were photographed under ultravi- olet light. Placement sites were compared according to the most appropriate and accurate position for insertion (within the area superior to the 6 th rib, posterior to pectoralis major and 1cm anterior to the mid-axillary line) as well as the British Thoracic Society’s ‘triangle of safety’. Comparisons of accuracy were made between participant rank (junior vs senior doctor), participant experience, simulated patient BMI category and placement side. Results: Insertion site was accurate in 47% of placements and within the ‘triangle of safety’ in 51% of placements. Improved accuracy was associated with greater participant experience (61% vs. 37%, p < 0.01), and left-sided chest placement (54% vs 40%, p = 0.02). No difference was found when comparing simulated patient BMI category (low vs high, 43% vs 51%, p = 0.18) or participant rank (junior vs senior, 41% vs 51%, p = 0.10). Conclusion: Overall accuracy of ICD insertion site was low, and appropriate accuracy was only associated with greater participant experience and left sided placement. Further studies to determine methods to improve ICD placement accuracy are needed.

Creator

Tessa Korda, Tammy Baillie-Stanton, LaraNicole Goldstein

Source

www.elsevier.com/locate/afjem

Publisher

elsevier

Date

25 October 2022

Contributor

peri irawan

Format

pdf

Language

english

Type

text

Files

Tags

,Repository, Repository Horizon University Indonesia, Repository Universitas Horizon Indonesia, Horizon.ac.id, Horizon University Indonesia, Universitas Horizon Indonesia, HorizonU, Repo Horizon ,

Citation

Tessa Korda, Tammy Baillie-Stanton, LaraNicole Goldstein, “Jurnal Internasional Afrika vol.12 issue 4 2022
African Journal of Emergency Medicine
An observational simulation-based study of the accuracy of intercostal drain placement and factors influencing placement,” Repository Horizon University Indonesia, accessed November 21, 2024, https://repository.horizon.ac.id/items/show/2091.