Jurnal Internasional Afrika vol. 13 issue 3 2023
African Journal of Emergency Medicine
An investigation into the use of Full-body Low Dose X-rays Imaging system in South Africa: Radiographer’s perspective

Dublin Core

Title

Jurnal Internasional Afrika vol. 13 issue 3 2023
African Journal of Emergency Medicine
An investigation into the use of Full-body Low Dose X-rays Imaging system in South Africa: Radiographer’s perspective

Subject

Lodox Ionising radiation Trauma imaging Conventional x-ray system patient referral emergency unit image quality

Description

Introduction: A low dose x-rays alias Lodox©statscan was originally developed in South Africa to detect smuggled diamonds in the mines. Later, hospital trauma units began to use it as a screening tool for gross pathology on trauma patients. This imaging system became popular because of its use of low radiation doses and its ability to perform anterior posterior (head to toe image) image in under 13 seconds. Anecdotal evidence confirms that patients were referred for additional regional images on conventional x-ray systems after Lodox imaging. Thus, patients were subjected to additional ionising radiation, long waiting times as well as additional charges for secondary radiological examinations. Objective: This research aimed at investigating the extent to which Lodox was used in trauma units (n = 28) in South Africa. Method: In this descriptive cross-sectional research. researcher invited one radiographer from each of the 28 hospitals in South Africa that were using Lodox. Results: Out of twenty radiographers who responded, it was found that most hospitals were referring patients for additional conventional x-ray images (Figure 1); for example, for chest x-rays. This was done despite the patient having undergone radiological procedures and examinations by the Lodox imaging system that was similar to those performed by conventional x-ray systems. Conclusion: Lodox was used for a successful diagnosis Thus, researcher recommends an imaging protocol for Lodox to be developed for guiding the referral of patients after the Lodox scanning has been performed

Creator

Muchui Julius Thambura

Source

www.elsevier.com/locate/afjem

Date

24 May 2023

Contributor

peri irawan

Format

pdf

Language

english

Type

text

Files

Citation

Muchui Julius Thambura, “Jurnal Internasional Afrika vol. 13 issue 3 2023
African Journal of Emergency Medicine
An investigation into the use of Full-body Low Dose X-rays Imaging system in South Africa: Radiographer’s perspective,” Repository Horizon University Indonesia, accessed December 3, 2024, https://repository.horizon.ac.id/items/show/2178.