Abstract -Damage to the oxygen regulator can cause the distribution of oxygen to the patient's body to be obstructed so that
the safety of the patient is safe. The purpose of this study is to make it easier for users to detect damage to regulators. The
contribution of this research is to design a device for monitoring the volume of oxygen that is equipped with detecting
damage to the regulator, as well as a central system and data storage to make it easier for users to document. To detect
damage to regulators quickly, a regulator detection system was created. The way this module works uses a level sensor in
the form of a photodiode and infrared to check the difference between the flowmeter sensor value and the sensor level
reading. Furthermore, the value comparison between the level sensor and the flowmeter sensor is used for regulator error
from the device or transmitter the data will be sent to the receiver wirelessly using a wifi connection, which will then be
received to the PC to be displayed on the Internet of Things (IoT) webserver. Testing of this device is done by comparing
the flow of the sensor reading the value with a standard measuring instrument. Based on the test results, the highest error
is 5.4% with a sensor level of 10 Lpm. For error detection, it displays error 1 and error 2 which is conditioned by clogging
the regulator used, and error 3 which is conditioned by closing the faucet in the oxygen reservoir slowly. The results of this
study can be implemented in an oxygen regulator as a patient safety for regulator damage.
Keywords: Oxygen Regulator, Safety, Flow Sensor, Level Sensor
Abstrak -Kerusakan pada regulator oksigen dapat menyebabkan distribusi oksigen pada tubuh pasien terhambat sehingga
membahayakan keselamatan pasien. Tujuan dari penelitian ini untuk memudahkan user dalam medeteksi kerusakan
regulator. Konstribusi dari penelitian ini adalah mendesain sebuah alat untuk monitoring volume oksigen yang dilengkapi
dengan deteksi kerusakan regulator, serta dilengkapi dengan system sentral dan penyimpanan data sehingga memudahkan
user dalam pendokumentasian. Agar kerusakan regulator dapat diketahui dengan cepat maka dibuat sistem deteksi
regulator. Cara kerja modul ini menggunakan sensor level berupa photodiode dan infrared untuk mendeteksi perbedaan
nilai sensor flowmeter dengan pembacaan sensor level. Selanjutnya perbandingan nilai antara sensor level dengan sensor
flowmeter digunakan untuk mendeteksi kerusakan regulator, dari alat atau transmitter akan dikirim datanya menuju
receiver secara wireless dengan menggunakan koneksi wifi, yang selanjutnya akan diterima ke PC untuk di tampilkan di
webserver Internet of Things (IoT). Pengujian alat ini dilakukan dengan membandingkan pembacaan nilai sensor flow
dengan alat ukur standar. Berdasarkan dari hasil pengujian, error tertinggi 5.4% dengan sensor level 10 Lpm. Untuk
deteksi error menampilkan error 1 dan error 2 yang dikondisikan dengan cara melakukan penyumbatan pada regulator
yang digunakan, dan error 3 yang dikondisikan dengan cara melakukan penutupan kran yang ada ditabung oksigen secara
perlahan. Hasil penelitian ini dapat di implementasikan pada alat regulator oksigen sebagai safety pasien akibat kerusakan
regulator.
Kata Kunci: Regulator Oksigen, Safety, Sensor Flow, Sensor Level
the safety of the patient is safe. The purpose of this study is to make it easier for users to detect damage to regulators. The
contribution of this research is to design a device for monitoring the volume of oxygen that is equipped with detecting
damage to the regulator, as well as a central system and data storage to make it easier for users to document. To detect
damage to regulators quickly, a regulator detection system was created. The way this module works uses a level sensor in
the form of a photodiode and infrared to check the difference between the flowmeter sensor value and the sensor level
reading. Furthermore, the value comparison between the level sensor and the flowmeter sensor is used for regulator error
from the device or transmitter the data will be sent to the receiver wirelessly using a wifi connection, which will then be
received to the PC to be displayed on the Internet of Things (IoT) webserver. Testing of this device is done by comparing
the flow of the sensor reading the value with a standard measuring instrument. Based on the test results, the highest error
is 5.4% with a sensor level of 10 Lpm. For error detection, it displays error 1 and error 2 which is conditioned by clogging
the regulator used, and error 3 which is conditioned by closing the faucet in the oxygen reservoir slowly. The results of this
study can be implemented in an oxygen regulator as a patient safety for regulator damage.
Keywords: Oxygen Regulator, Safety, Flow Sensor, Level Sensor
Abstrak -Kerusakan pada regulator oksigen dapat menyebabkan distribusi oksigen pada tubuh pasien terhambat sehingga
membahayakan keselamatan pasien. Tujuan dari penelitian ini untuk memudahkan user dalam medeteksi kerusakan
regulator. Konstribusi dari penelitian ini adalah mendesain sebuah alat untuk monitoring volume oksigen yang dilengkapi
dengan deteksi kerusakan regulator, serta dilengkapi dengan system sentral dan penyimpanan data sehingga memudahkan
user dalam pendokumentasian. Agar kerusakan regulator dapat diketahui dengan cepat maka dibuat sistem deteksi
regulator. Cara kerja modul ini menggunakan sensor level berupa photodiode dan infrared untuk mendeteksi perbedaan
nilai sensor flowmeter dengan pembacaan sensor level. Selanjutnya perbandingan nilai antara sensor level dengan sensor
flowmeter digunakan untuk mendeteksi kerusakan regulator, dari alat atau transmitter akan dikirim datanya menuju
receiver secara wireless dengan menggunakan koneksi wifi, yang selanjutnya akan diterima ke PC untuk di tampilkan di
webserver Internet of Things (IoT). Pengujian alat ini dilakukan dengan membandingkan pembacaan nilai sensor flow
dengan alat ukur standar. Berdasarkan dari hasil pengujian, error tertinggi 5.4% dengan sensor level 10 Lpm. Untuk
deteksi error menampilkan error 1 dan error 2 yang dikondisikan dengan cara melakukan penyumbatan pada regulator
yang digunakan, dan error 3 yang dikondisikan dengan cara melakukan penutupan kran yang ada ditabung oksigen secara
perlahan. Hasil penelitian ini dapat di implementasikan pada alat regulator oksigen sebagai safety pasien akibat kerusakan
regulator.
Kata Kunci: Regulator Oksigen, Safety, Sensor Flow, Sensor Level
Creator
Dwi SitiNurhayati#
, Bambang Guruh Irianto, Abd. Kholiq
, Bambang Guruh Irianto, Abd. Kholiq
Source
semnas.poltekkesdepkes-sby.ac.id
Date
Surabaya, 28 Nopember 2020
Contributor
PERI IRAWAN
Format
PDF
Language
INDONESIA
Type
TEXT
Files
Citation
Dwi SitiNurhayati#
, Bambang Guruh Irianto, Abd. Kholiq, “PROSIDING-NASIONAL-KEBIDANAN-2020 POLTEKES KEMENKES CALL FOR PAPER VOL.2 NO 1
Pengembangan Monitoring Volume Oksigen
Dilengkapi Dengan Deteksi Kerusakan Regulator
untuk Safety Pasien Berbasis IoT,” Repository Horizon University Indonesia, accessed April 9, 2025, https://repository.horizon.ac.id/items/show/141.
Pengembangan Monitoring Volume Oksigen
Dilengkapi Dengan Deteksi Kerusakan Regulator
untuk Safety Pasien Berbasis IoT,” Repository Horizon University Indonesia, accessed April 9, 2025, https://repository.horizon.ac.id/items/show/141.