Safety and Health at Work Vol. 10 Issue 3 2019
Exposure to Particles and Nitrogen Dioxide Among Workers in the Stockholm Underground Train System (Original Article)
Dublin Core
Title
Safety and Health at Work Vol. 10 Issue 3 2019
Exposure to Particles and Nitrogen Dioxide Among Workers in the Stockholm Underground Train System (Original Article)
Exposure to Particles and Nitrogen Dioxide Among Workers in the Stockholm Underground Train System (Original Article)
Subject
Airborne exposure, Occupation, Particle exposure, Subway
Description
Objectives: Exposure to fine particles in urban air has been associated with a number of negative health effects. High levels of fine particles have been detected at underground stations in big cities. We investigated the exposure conditions in four occupational groups in the Stockholm underground train system to identify high-exposed groups and study variations in exposure.
Methods: PM1 and PM2.5 were measured during three full work shifts on 44 underground workers.
Fluctuations in exposure were monitored by a real-time particle monitoring instrument, pDR, DataRAM. Qualitative analysis of particle content was performed using inductively coupled plasma mass spectrometry. Nitrogen dioxide was measured using passive monitors.
Results: For all underground workers, the geometric mean (GM) of PM1 was 18 mg/m3 and of PM2.5 was 37 mg/m3. The particle exposure was highest for cleaners/platform workers, and the GM of PM1 was 31.6 mg/m3 [geometric standard deviation (GSD), 1.6] and of PM2.5 was 76.5 mg/m3 (GSD, 1.3); the particle exposure was lowest for ticket sellers, and the GM of PM1 was 4.9 mg/m3 (GSD, 2.1) and of PM2.5 was 9.3 mg/m3 (GSD, 1.5). The PM1 and PM2.5 levels were five times higher in the underground system than at the street level, and the particles in the underground had high iron content. The train driver’s nitrogen dioxide exposure level was 64.1 mg/m3 (GSD, 1.5).
Conclusions: Cleaners and other platform workers were statistically significantly more exposed to par-
ticles than train drivers or ticket sellers. Particle concentrations (PM2.5) in the Stockholm underground system were within the same range as in the New York underground system but were much lower than in several older underground systems around the world.
Methods: PM1 and PM2.5 were measured during three full work shifts on 44 underground workers.
Fluctuations in exposure were monitored by a real-time particle monitoring instrument, pDR, DataRAM. Qualitative analysis of particle content was performed using inductively coupled plasma mass spectrometry. Nitrogen dioxide was measured using passive monitors.
Results: For all underground workers, the geometric mean (GM) of PM1 was 18 mg/m3 and of PM2.5 was 37 mg/m3. The particle exposure was highest for cleaners/platform workers, and the GM of PM1 was 31.6 mg/m3 [geometric standard deviation (GSD), 1.6] and of PM2.5 was 76.5 mg/m3 (GSD, 1.3); the particle exposure was lowest for ticket sellers, and the GM of PM1 was 4.9 mg/m3 (GSD, 2.1) and of PM2.5 was 9.3 mg/m3 (GSD, 1.5). The PM1 and PM2.5 levels were five times higher in the underground system than at the street level, and the particles in the underground had high iron content. The train driver’s nitrogen dioxide exposure level was 64.1 mg/m3 (GSD, 1.5).
Conclusions: Cleaners and other platform workers were statistically significantly more exposed to par-
ticles than train drivers or ticket sellers. Particle concentrations (PM2.5) in the Stockholm underground system were within the same range as in the New York underground system but were much lower than in several older underground systems around the world.
Creator
N. Plato, C. Bigert, B.-M. Larsson, M. Alderling, M. Svartengren, P. Gustavsson
Publisher
Elsevier Korea LLC
Date
September 2019
Contributor
Sri Wahyuni
Format
PDF
Language
English
Type
Text
Coverage
Safety and Health at Work Vol. 10 Issue 3 2019
Files
Citation
N. Plato, C. Bigert, B.-M. Larsson, M. Alderling, M. Svartengren, P. Gustavsson , “Safety and Health at Work Vol. 10 Issue 3 2019
Exposure to Particles and Nitrogen Dioxide Among Workers in the Stockholm Underground Train System (Original Article),” Repository Horizon University Indonesia, accessed November 21, 2024, https://repository.horizon.ac.id/items/show/1938.
Exposure to Particles and Nitrogen Dioxide Among Workers in the Stockholm Underground Train System (Original Article),” Repository Horizon University Indonesia, accessed November 21, 2024, https://repository.horizon.ac.id/items/show/1938.